| Fan: |
|
| Flow: |
Accuracy ±5%, ±3% with Auto Correct in Retrotec software |
| Maximum Flow in Free Air |
6,300 CFM | 2,973 Litres/s | 10,705m3/h |
| Maximum Flow at 50 Pascal test pressure: |
5,600 CFM | 2,643 Litres/s | 9,514m3/h |
| Minimum Flow on Range Configuration C1 at 10 Pa |
38 CFM | 18 Litres/s | 65 m3/h |
| Dimensions: |
|
| Height: |
26" (66cm) |
| Depth: |
9.5" (24.1cm) |
| Inlet Diameter: |
22" (56 cm) |
| Weight: |
34lbs (15.4kg) |
| Motor: |
0.75hp, 9.8 amps at 120V, 4.5 amps at 240V |
| Calibration meets: |
Canadian CGSB-149.1-2002 & Super E, USA ASTM E779 – European EN 13892 & CEN, UK TM-23 Energy Standards, Rain Penetration Standards. NFPA 1001 - 01, ISO 14520 and UBC-905 fire standards |
| Door Panel: |
|
| Panel Case: |
31" x 30" x 7" (77cm x 76cm x 18cm) |
| Panel Height (min/max): |
76.5" to 87" (194cm to 221cm) |
| Panel Width (min/max): |
28.5" to 41.5" (72.4cm to 105.4cm) |
| Panel Weight: |
21.5lb (9.8kg) |
| DM-2A Digital Pressure Gauge: |
|
| Pressure Chanels: |
2 independent pressure channels (A & B) |
| Pressure Range: |
-1250 Pa to +1250 Pa (-5" to +5" H2O |
| Resolution: |
0.01 Pa (0.0001" H2O, 0.001 lb/ft2) |
| Accuracy: |
1% of pressure reading or 0.15 Pa (whichever is greater) |
| Weight: |
14oz (397g) |
| Dimensions: |
8.75" x 4.25" x 3" (22.2cm x 10.8cm x 7.6cm) |
| LCD Display: |
2.4" x 1.4" (6cm x 3.6cm) |
| Operating Temperature Range: |
32°F to 130°F (0°C to 53°C) |
| Display Backlight: |
Press [ON] to activate |
| Power: |
4 x NiMH rechargable batteries and charger included |
| Auto Off: |
4 hours |
| Temperature: |
Can be displayed with Retrotec’s temperature probe (optional) |
| Calibration meets: |
Canadian CGSB-149.1-2002 & Super E, USA ASTM E779 – European EN 13892 & CEN, UK TM-23 Energy Standards, Rain Penetration Standards. NFPA 1001 - 01, ISO 14520 and UBC-905 fire standards |
| Supported Units of Measurement: |
|
| Channel A: |
Pressure in Pascals, inches H2O, lb/ft2 |
| Channel B: |
Pressure in Pascals, inches H2O, lb/ft2
OR Flow in cfm, l/s, m3/s, m3/h
OR Flow @ (any pressure) calculates ELA at ANY desired pressure configured in the Setup menu
OR Leakage Area – EqLA (Canadian) and/or EfLA (US) in cm2, in2, ft2
OR Leakage Area @ (any pressure) calculates ELA at ANY desired pressure configured in Setup menu
OR Air-changes per hour according to volume entered in keypad
OR Velocity in m/s, km/h, ft/s, ft/min, mph
OR Velocity-Flow in cfm, l/s, m3/s, m3/h according to cross-sectional area entered on keypad |
| Functionality: |
|
| Range/Config: |
Cycles through flow ranges of the blower door or duct tester being used |
| Setup: |
Permits changing default units, displayed outputs, devices and reference pressures |
| Baseline: |
Measures and removes background pressures on Channel A for subequent testing |
| Time Avg: |
Advanced box-car averaging displays continuous updates of the average pressure. No more waiting for your next average pressure measurement! Dramatically reduces the affect of wind and other pressure fluctuations |
| Auto Zero: |
On start-up and every 8 seconds on both channels. May be turned off |
| Device: |
Selects the flow characteristics of virtually any blower door, duct-tester or a pilot tube |
| @: |
Turns on/off extrapolation to configured pressures |
| Volume/Area: |
Enter volume and/or area values to calculate air-change and flow/unit area results. |
| Temperature: |
Displayed with Retrotec’s temperature probe (optional) |
| Set Speed: |
Allows direct control of fan speed from the DM-2 – no need for handheld speed control |
| Set Flow: |
Closed-loop PID control of fan flow pressure – great for windy conditions |
| Set Pressure: |
Permits “set and forget” control of your fan. Dial in “Set 50 Pa” and the fan will ramp up and hold 50 Pa giving on the fly flow, ACH or leakage measurements. As you identify and seal leaks, the fan will automatically adjust itself for the tighter enclosure |